beautypg.com

3 independent operation - remote sensing, Independent operation - remote sensing -6 – KEPCO RA 19-1U Operator Manual User Manual

Page 22

background image

2-6

RA 19-1U 020413

2.4.1.3

INDEPENDENT OPERATION - REMOTE SENSING

Remote sensing is accomplished by connecting +Load to (S+) and –Load to (S–). Figure 2-4
illustrates remote sensing for PS1 and PS2 using wires connected to the I/O mating connector.

NOTE: The rear panel DIP switch settings established at the factory for positions 1 and 2 of

the associated DIP switch MUST be changed to OFF (open) if this option is chosen.

Positions 3 and 4 (connecting sense lines in parallel) and Position 5 (current share) must be set
to OFF. Configure Positions 6, 7, and 8 (alarms) per PAR. 2.4.4.

FIGURE 2-4. INDEPENDENT OPERATION, REMOTE SENSING FOR PS1 AND PS2 USING

EXTERNAL WIRING AT I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM