RA 19-1U 020413

2-9

2.4.2.2.2 PARALLEL CURRENT SHARE - EXTERNAL WIRING

Only slots 1 and 4 can be configured for parallel operation using external wiring; To configure
slots 2 and 3 for parallel operation with current sharing the rear panel DIP switches must be
used (see PAR. 2.4.2.2.1). The Current Share lines for each supply must be connected
together at the I/O mating connector (pin 4) using external wiring (see Figure 2-6). Figure 2-6 is
a simplified diagram of a parallel configuration for slots 1 and 4 using external wiring at the I/O
mating connector.

FIGURE 2-6. PARALLEL OUTPUTS USING EXTERNAL WIRING, TYPICAL

CONFIGURATION, SIMPLIFIED DIAGRAM

I/O CONNECTOR,
PS3, PS4

I/O CONNECTOR,
PS1, PS2