2-14

RA 19-1U 020413

2.4.2.3.4 PARALLEL CONFIGURATIONS USING EXTERNAL WIRES TO CONNECT SENSE LINES

IN PARALLEL AND EXTERNAL WIRES TO CONFIGURE REMOTE SENSING

Figure 2-10 is a simplified diagram of a typical parallel configuration using remote sensing via
external wires to connect V(+) to S(+), V(–) to S(–) and jumpers connected to the mating con-
nector to connect the sense leads in parallel. This configuration requires the following:

1. For each supply in parallel set DIP switch positions 1 and 2 to OFF (open) (see Figure 1-3).

2. For each DIP switch between parallel-connected slots (DIP 2), set DIP switch positions 3

and 4 to OFF (open) (sense leads will be connected in parallel in steps 7 and 8) (see Figure
1-3).

3. For each DIP switch between parallel-connected slots, configure position 5 to connect the

current share bus by referring to PAR. 2.4.2.2.

4. Configure Positions 6, 7, and 8 (alarms) of each DIP switch per PAR. 2.4.4.

5. Connect short jumper across I/O mating connector Sense (+) pins.

6. Connect short jumper across I/O mating connector Sense (–) pins.

7. Connect wire from I/O mating connector Sense (+) pin to V (+) at the load.

8. Connect wire from I/O mating connector Sense (–) pin to V (–) at the load.

FIGURE 2-10. TYPICAL PARALLEL CONNECTIONS, REMOTE SENSING USING I/O MATING

CONNECTOR JUMPERS TO PARALLEL SENSE WIRES