Rugged Cams ELX DVR 16 Channel User Manual
Page 63
Basic Configuration
ELX16-240
Rugged CCTV.
2003.09.06 (v 1.0)
63
Keyboard Control Addr
To set keyboard’s control address in order to operate all ELX16 -240’s menus with keyboard. Default
value is “32”. If several ELX16-240s are connected with one keyboard, it can be collided. Then the
default value should be changed.
Keyboard PTZ Addr
To set keyboard’s PTZ address in order to operate each PTZ camera with keyboard. If setting just first
camera’s address of each ELX16-240, another cameras ’ are designated automatically. For example, 1
st
ELX16 -240 has five cameras and 2
nd
ELX16-240 has six cameras, keyboard PTA address of 1
st
ELX16-
240 should be set as “1” and one of 2
n d
ELX16-240 be set as “6”. Be cautious that PTZ addressed are
assigned to all cameras automatically in spite of non PTZ camera.
DVR ID
For use with the DVR Manager to control and manage several ELX16-240s .
Language
To select the language used for the OSD Menu.
Reset Values
To reset current configured values. To reset DVR, press the “Reset Values ” button.