WatchOUT PIR Installation Manual

DIP Switch Settings

1

2

3

4

5

6

7

8

ON

Factory

Default

DIP 1

: LEDs operation

On

: LEDs enabled

Off

: LEDs disabled

DIP 2-3

: PIR Detection Sensitivity

Sensitivity

DIP2

DIP3

Low

Off

Off

Mid

Off

On

Normal

On

Off

Maximum

On

On

DIP 4

: Auxiliary relay control

ON

: Enabled

OFF

: Disabled

DIP 5

: Used to define the auxiliary relay operation

following an alarm condition, depending on
Day/Night time (defined by 24 Hours / Night
Photocell)

ON

(Night): Auxiliary relay is activated only

during nighttime.

OFF

(24 Hours): Auxiliary relay is activated

24 hour

DIP 6-7

: Defines the time duration that the auxiliary

relay is activated

Activation Time

Switch 6

Switch 7

2.2 seconds

OFF

OFF

2.0 Minutes

OFF

ON

4.0 Minutes

ON

OFF

8.0 Minutes

ON

ON

DIP 8

: Red LED /3 LED

ON

: Red LED only

OFF

: 3 LEDs

Detection Range Adjustment

Slide the moving PIR to the desired
position, see figure 6.

The range of the lower detection area
determines the detection range.
The upper PIR is fixed and its detection
area is parallel to the ground at all times.
The lower detection area changes from
2m to 12m depending on the location of
the moving PIR. Therefore, the detection
range is established according to the
location of the lower PIR since both the
upper and the lower PIR should be
triggered in order to activate an alarm.

Figure 6