beautypg.com

System parameters – RISCO Group WatchIN Industrial Grade 3 Detector User Manual

Page 21

background image

WatchIN Installation Manual

19

Quick Keys

Parameter

Default

guidelines by avoiding surplus emission.

[2][0][3][zzz]
[8][1]

No
Green Line feature in disabled: MW is constantly activated

[2][0][3][zzz]
[8][2]

Yes
Green Line feature is enabled

[2][0][3][zzz]
[9]

SWAY Yes
This option allows the recognition and immunity of swaing objects in a
known patern.

[2][0][3][zzz]
[9][1]

No
Sway is disabled

[2][0][3][zzz]
[9][2]

Yes
Sway is enabled

System Parameters

System: System Control

Quick Keys

Parameter

[1][2][36]

(UK Version)

AM=Tamper

Default: No

Used to determine the operation of Anti Masking detection
Yes: Anti mask violation will activate tamper alarm.
No: Anti mask violation will be regarded as trouble event.

[1][2][37]

VBR=Tamper

No

Used to determine the operation of the vibration detection (applicable to
versions with Vibration sensor installed)
Yes: Vibration detection will activate tamper alarm.
No: Vibration detection will be regarded as trouble event.