beautypg.com

Precision Digital PD865 User Manual

Page 33

background image

PD865 Snooper Modbus

Serial Input Meter

Instruction Manual

33

The following table shows the system setup for the MTS M-Series
gauge, the PD865 Master, and the two PD865 Snoopers:

Parameter

PD865
Master

PD865
Snooper 1

PD865
Snooper 2

Mode Master

Snooper

Snooper

Function Code

04

04

04

Number of PVs

3

N/A

N/A

Slave ID

247

247

PV1 247

PV2 247

PV3 247

Register Number

30003

30017

Reg.PV1 30001

Reg.PV2

30003 (2 Reg.)

Reg.PV3

30017 (2 Reg.)

Data Type

Long integer
Binary, Signed

Long Long

Byte Order

1234

1234

1234

Polling Time

2.0 sec

10.0 sec

10.0 sec

Slave Response
Timeout

5.0 sec

N/A

N/A

Baud 4800

4800

4800

Parity No No

No

Byte-to-Byte
Timeout

0.01 sec

0.01 sec

0.01 sec

Decimal point

2 places

2 places

2 places

Input 1

-199999

-199999

-199999

Display 1

-1999.99

-1999.99 -1999.99

Input 2

999999

999999

999999

Display 2

9999.99

9999.99

9999.99