17-FAULTS/CAUSES/SOLUTIONS

Technical Dept. - All rights reserved - Reproduction is prohibited

ANOMALIES RELATED TO THE HYDRAULIC CIRCUIT

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

No increase in temperature with stove in

operation

Incorrect combustion adjustment

Check recipe

Boiler / system dirty.

Check and clean the boiler

Insufficient stove power

Check that the stove is properly sized for the

requirements of the system

Poor pellet quality

Use pellets from the producer

Condensation in boiler

Incorrect boiler or pump temperature

setting

Set the stove or the pump to a higher

temperature

Insufficient fuel consumption

Check recipe

Radiators cold in winter

Room thermostat (local or remote) set

too low. If remote thermostat, check if it

is defective.

Set to higher temperature or replace. (if

remote)

Circulator does not run because it is

blocked

Free up the circulator by removing

the plug and turning the shaft with a

screwdriver

Circulator does not run

Check the electrical connections of the

circulator; replace if necessary

Radiators have air in them

Vent the radiators

Hot water is not provided

Circulator (pump) blocked

Free the circulator (pump)

If the stove is NOT used as described in this instruction booklet, the manufacturer refuses to accept any responsibility

for damage to persons and property that may arise. The manufacturer furthermore refuses to accept responsibility

for damage to persons and property arising from the failure to observe all the rules contained in the manual and

in particular:

• The operations in italics must be carried out by specialised personnel from the manufacturer

• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and

repairs.

• Do not tamper with the safety devices.

• Do not remove the safety devices.

• Connect the stove to an efficient smoke extraction system.

• First, check that the environment where it is to be installed is properly ventilated.

This manual is related to the following products: