17-FAULTS/CAUSES/SOLUTIONS

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

The stove runs for a few minutes and then

goes out

Start-up phase is not completed

Repeat start-up

Temporary power cut

Wait for the automatic restart

Clogged smoke duct

Clean the smoke duct

Faulty or malfunctioning temperature

probes

Check and replace the probes

Pellets accumulate in the brazier, the glass

of the door gets dirty and the flame is

weak

Insufficient combustion air

Make sure that the air inlet in the room is

fitted and clear. Check that the combustion

air filter on the Ø 5 cm air inlet pipe is not

clogged. Clean the brazier and check that

all the holes are clear. Perform a general

cleaning of the combustion chamber and

the smoke duct. Check the condition of the

door gaskets

Damp or unsuitable pellets

Change the type of pellets

Faulty smoke evacuation motor

Check the motor and replace it, if neces-

sary

The smoke evacuation motor does not

work

No electrical supply to the stove

Check the mains voltage and the

protection fuse

Motor block caused by clogging.

Perform a general cleaning of the

combustion chamber and the smoke duct.

The motor is faulty

Check the motor and capacitor and

replace them, if necessary

Defective motherboard

Replace the electronic board

Control panel broken

Replace the control panel

The stove does not run

No power supply

Check that the plug is inserted and the

main switch is in the “I” position

Pellet or water probe fault

Wait for the pellet or water tank to cool

down and restart the stove

Blown fuse

Replace the fuse

Faulty spark plug

Check the spark plug and replace it, if

necessary