Cd b, Settings menu – MCZ Duo HYDRO AIR User Manual
Page 30
30
12-SETTINGS MENU
ROOM INPUT
The room input is used to set the probe or the thermostat at terminals 3-4 of the back terminal board of the stove.
The stove has the room probe set as default factory settings.
Selecting the thermostat it is possible to replace the probe on the stove with a thermostat that requests heat when the contact is closed.
To enter the function press:
from the settings menu - press ok (E key), press the D key (arrow) and scroll up to Room Input, press OK (E key) and select room thermostat,
press E key to confirm.
Attention!!! If room temperature is selected, weekly hourly programming is not available.
PUMP ON T
This function enables adjustment of the pump activation temperature.
To enter the function press:
from the Settings menu- press ok (E key), press the C-D key (arrow) and scroll up to temp.On pump, press OK (E key)- Modify the
temperature using the central C and D keys, press the E key to confirm.
B
E
INFO
OK
C
D
B
EXIT
SET AMBIENT INPUT AS A PROBE OR
THERMOSTAT.
(TERMINALS 3 - 4)
SETTING-INPUT AMB
PROBE
AMB.
THERMOSTAT
AMB.
B
E
INFO
OK
C
D
B
EXIT
MINIMUM TEMPERATURE OF THE
WATER TO START THE PUMP
OF THE BOILER
SETTINGS-T.ON PUMP
60°