14-SAFETY DEVICES AND ALARMS

Technical Dept. - All rights reserved - Reproduction is prohibited

WRITTEN ON THE

DISPLAY

TYPE OF PROBLEM

SOLUTION

A08

FLUE GAS FAN

Faulty smoke fan.

Check that the lower compartment is clean (see

dedicated stove cleaning pages) and verify that it is

not obstructed, is clean and cancel the alarm.

If the alarm persists, contact the service centre.

A09

SMOKE TEMPERA-

TURE PROBE

Smoke sensor fault.

Contact an authorised service centre to have the

component replaced and, if needed, replace the

component.

A11

GEAR REDUCER

Auger gear reducer fault.

The component is not working regularly.

Contact an authorised service centre to have the

component replaced and, if needed, replace the

component.

A13

BOARD TEMP

Electronic board overheating

Wait for the cooling phase to end, cancel the alarm

and reduce pellet loading (SETTINGS MENU - Pellet

recipe). If the alarm persists, contact the service

centre. .

A14

ACTIVE SENSOR

Active sensor anomaly

Active Plus sensor operation anomaly. Contact an

authorised service centre to have the component

replaced and, if needed, replace the component.

A18

WATER SIC

Water thermostat intervention

Water temperature is too high or thermostat

operational anomaly. If the alarm persists, contact the

service centre.

A19

WATER PROBE

Fault with water sensor

Possible fault in the safety component. Contact an

authorised service centre to have the component

replaced and, if needed, replace the component.

A20

AUX PROBE

Auxiliary probe fault

Possible component fault.

Check that the probe inserted in the system respects

the characteristics specified in the instructions (see

external probe).

Contact an authorised service centre to have the

component replaced and, if needed, replace the

component.

Exiting the alarm conditions

NEVER open the appliance door whilst the stove is either in the initial startup or on its shut down cycle, pellets will

still be smoldering or therefore volatiles may be present.

ATTENTION!

If during operation or initial ignition you encounter smoke spillage in to the room from the appliance or the flue

then please switch off the appliance, ventilate the room and contact the installation / service engineer immediately.