Settings menu – MCZ Duo HYDRO AIR User Manual
Page 17

17
12-SETTINGS MENU
Technical Dept. - All rights reserved - Reproduction is prohibited
HYDRO AIR
The Hydro Air function can be activated/deactivated manually or managed automatically (factory default setting).
In Hydro-Air On mode the internal three-way valve is switched so that the water, before going towards the system, passes through the
front radiator, transferring heat to the environment through the fan up to 6 kW (at maximum power with water temperature at 70°C).
In Hydro-Air Off mode the internal three-way valve is switched so that stove water goes directly to the system, without passing through
the front radiator. In this case power released to the environment may reach 3 kW.
In Hydro-Air Automatic mode the three-way valve is managed in an intelligent way by the electronic control in order to release
maximum power to the room only when there is an actual heat request from the stove probe. If there is no request from the room, the
valve is switched as in OFF mode.
To enter the function:
from the settings menu - press ok (E key), press the D key (arrow key) and scroll up to Hydro-air, press OK (E key) and activate the HYD-AIR
AUTO / HYD-AIR ON / HYD-AIR OFF function and press ok "E" key to confirm.
AUGER LOADING (only with the stove off)
This function is for filling the pellet loading system. Can only be activated with the stove off.
To enter the function:
from the settings menu - press ok (E key), press the D key (arrow key) and scroll up to load auger, press OK (E key) and activate/deactivate
the function, press ok ("E" key) to confirm.
B
E
INFO
OK
C
D
HYD-AIR
AUTO
B
EXIT
ON = MAX POWER TO AMBIENT
OFF =MAX POWER TO HYDRO PLANT
AUTO=AUTOMATIC OPERATION
SETTINGS-HYDRO-AIR
HYD-AIR
ON
HYD-AIR
OFF
B
E
INFO
OK
C
D
DEACTIVATE
LOAD
B
EXIT
USE THE 'FEED SCREW LOADER' WHEN
THE FEED SCREW IS EMPTY AND
YOU MUST LOAD IT QUICKLY
SETTINGS-FEED SCR LOAD
ACTIVATE
LOAD