50

14-CLEANING

CHECK EVERY 2 / 3 DAYS

Clean and empty any ash or deposits from ash pan “E” and brazier “L” that might obstruct the air flow holes, paying attention to any hot

ashes.

If the pellets in the hopper run out, unburned pellets may accumulate in the brazier. Always empty the residue in the brazier before each

start-up.

You may only use a vacuum cleaner to remove ash when it is completely cold. In this case, use a suitable vacuum cleaner to

remove small sized particles. The quality of the pellets used and user experience will determine the cleaning frequency required.

However, it is recommended not to exceed 2 or 3 days.

CLEANING THE GLASS

It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specific detergent and clean with a cloth.

ATTENTION!

Do not use abrasive products and do not spray the glass cleaning product on the painted parts and on the door

gaskets (ceramic fibre cord).