beautypg.com

Emergency panel – MCZ Vivo 90 Pellet Comfort Air User Manual

Page 46

background image

44

10-EMERGENCY PANEL

Feed screw loading function

This function can only be activated when the stove is off and allows the pellets to be loaded into the loading system (feed screw). It can

be used each time the pellets finish in the hopper (see alarm A02). It is useful to prevent failed start-ups (alarm A01) due to the hopper

being empty.

Enable the function as follows:

• Set the first selector to OFF

• Set the second selector to MED

• Make sure that OFF appears on the display because this function can only be activated with the stove completely cold (off) and the

selector set to OFF.

• Press the TEST key 3 times consecutively within 2 seconds

• FEED SCREW will appear on the display in two subsequent intervals.

• Press the TEST key once again when the pellets begin to fall into the brazier to end the FEED SCREW LOADING function or wait for

the function to end on its own

• Proceed with lighting the stove.