beautypg.com

Extron electronic MEDIALINK MLC 52 User Manual

Page 23

background image

2-13

MLC 52 Series MediaLink Controllers • Installation

3

.

Attach a 3.5 mm, 5-pole captive screw connector to one end of the cable and a
6-pole captive screw connector to the other end. Only three wires are
required:

A

(MLC) to A (IR Link)

B

(MLC) to B (IR Link)

C

(MLC) to D (IR Link)

Connect the wires as shown in the illustration below. Connectors are
included with the IR Link, but the cable must be purchased separately.

4

.

Plug the 5-pole connector into one of the IR Link’s communications
connectors.

5

.

Plug the 6-pole connector into the rear panel control port of the MLC 52.

Wiring and using the IR Link for IR remote control

Do not connect more than one IR Link, either in parallel or in series.

IR Link

F E D C B A

A B C D E

D
B
A

Modulated IR

+12VDC

Ground ( )

MLC 52
Control
Port

IR in

C
B
A

Total distance
from MLC is
150' (45.7 m) max.

SIGNAL

IR LINK

IR Link
IR Signal
Repeater

SIGNAL

IR LINK

MLC 52 or MLC 52 VC

MLC 52

DISPLAY

ON

PC

VIDEO

OFF

VOL

VOL

IR 452 Remote
Control

SY
STEM REMO

TE

FR
ONT P

ANEL

DV
D

VCR

DV
D

VCR

TV/VCR

VO

L

VO

L

PC

VIDEO

CHANNEL

IR 452

40

40

30’ (12 m)
max.