beautypg.com

Installation, cont’d, Wiring the control connector – Extron electronic MEDIALINK MLC 52 User Manual

Page 20

background image

Installation, cont’d

MLC 52 Series MediaLink Controllers • Installation

2-10

Wiring the control connector

The display and source control connector allows you to connect cables for IR
devices, RS-232 devices (RS models only), and AC power to the MLC. The
illustration below shows the pin assignments of the MLC’s control connector that
are covered in detail on the following pages.

IR in

12 V DC in

F E D C B A

RS-232 Tx (RS models only)
IR out

Pinout guide for the MLC 52 display/source control connector

The ports in this connector, from left to right, perform the following functions:

F (Tx)

— Transmits the RS-232 signal for projector control.

Although this port is present on both the IR and the RS models, it is functional
only on the RS models.

E (IR out)

— Used for connecting an IR emitter to issue IR commands. Up to two

emitters can be wired to this port.

D (GND)

— Ground for IR and/or RS-232 projector control

C (IR in)

— Used for connecting an optional IR Link or IRL 20, so that an IR remote

can control the MLC.

B (GND)

Ground for the +12 VDC power

A (+12 V)

— Power input for the product (12 VDC)

The two-gang MLC 52 IR VC and MLC 52 RS VC have the same control
ports as the one-gang models.