VCCI NOTICE

This is a class A product based on the standard of the Voluntary Control Council for Interference by Information 
Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. 
When such trouble occurs, the user may be required to take corrective actions.

BSMI EMC STATEMENT — TAIWAN

This is a class A product. In a domestic environment this product may cause radio interference in which case the user 
may be required to take adequate measures.

SAFETY INFORMATION

CLASS 1 LASER TRANSCEIVERS

SINGLE MODE NETWORK EXPANSION MODULES USE CLASS 1 LASER TRANSCEIVERS.

READ THE FOLLOWING SAFETY INFORMATION

BEFORE INSTALLING OR OPERATING THESE MODULES.

The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop 
eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user 
adjustment. Class 1 Laser transceivers comply with the following safety standards:

• 21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA).

• IEC Publication 825 (International Electrotechnical Commission).

• CENELEC EN 60825 (European Committee for Electrotechnical Standardization).

When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission 
limit of all three standards. Class 1 levels of laser radiation are not considered hazardous.

When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power 
exiting the fiber (under normal conditions) is ‐12.6 dBm or 55 x 10

‐6

 watts.

Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The 
maximum radiance from the optical port (under worst case conditions) is 0.8 W cm

‐2

 or 8 x 10

3

 W m

2

 sr‐1. 

Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases 
eye hazard. When viewing the output optical port, power must be removed from the network adapter.