Installing optional xfps, Preparation, Installing optional xfps -3 – Enterasys Networks C2K122-24 User Manual
Page 33: Preparation -3
Installing Optional XFPs
SecureStack C2 Installation Guide 3-3
Installing Optional XFPs
This section describes how to install XFPs in port slots 25 and 26. It is recommended that
you install any options before installing the switch.
Preparation
Before installing the XFP, proceed as follows:
1.
Before removing the XFP from the antistatic packaging, it is recommended that you
use an antistatic wrist strap (not supplied) to prevent damage from static discharge.
To use the wrist strap, refer to the instructions provided with your antistatic wrist
strap.
2.
Remove the XFP from its packaging.
3.
If there is a protective dust cover (see 5 in
) in the XFP connector, do not
remove it at this time.
Warning: Fiber-optic XFPs use Class 1 lasers. Do not use optical instruments to view the
laser output. The use of optical instruments to view laser output increases eye hazard.
When viewing the output optical port, power must be removed from the network adapter.
Advertencia: Los XFPs de fibra optica usan lasers de clase 1. No se debe usar
instrumentos opticos para ver la potencia laser. El uso de los instrumentos opticos para
ver la potencia laser incrementa el riesgo a los ojos. Cuando vean el puerto de la potencia
optica, la corriente debe ser removida del adaptador de la red.
Warnhinweis: XFPs mit Fiber-Optik Technologie benutzen Laser der Klasse 1. Benutzen
sie keinesfalls optische Hilfsmittel, um die Funktion des Lasers zu überprüfen. Solche
Hilfsmittel erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port überprüfen
möchten stellen Sie sicher, dass die Komponente von der Spannungsversorgung getrennt
ist.
Caution: Carefully follow the instructions in this manual to avoid damaging the XFP and
switch.
The XFP and switch are sensitive to static discharges. Use an antistatic wrist strap and
observe all static precautions during this procedure. Failure to do so could result in
damage to the XFP and switch. Always leave the XFP in the antistatic bag or an equivalent
antistatic container when not installed.
Precaución: Siga las instrucciones del manual para no dañar el XFP ni del aparato,
puesto que son muy sensible a las descargas de electricidad estática. Utilice la pulsera
antiestática y tome todas las precauciones necesarias durante este procedimiento. Si no
lo hace, podría dañar el XFP o del aparato. Mientras no esté instalado, mantenga el XFP
en su bolsa antiestática o en cualquier otro recipiente antiestático.