Edge Products ES3528-WDM User Manual
Page 98
Simple Network Management Protocol
5-14
5
linkUp
1.3.6.1.6.3.1.1.5.4
A linkUp trap signifies that the SNMP entity,
acting in an agent role, has detected that the
ifOperStatus object for one of its communication
links left the down state and transitioned into
some other state (but not into the notPresent
state). This other state is indicated by the
included value of ifOperStatus.
authenticationFailure
1.3.6.1.6.3.1.1.5.5
An authenticationFailure trap signifies that the
SNMPv2 entity, acting in an agent role, has
received a protocol message that is not properly
authenticated. While all implementations of the
SNMPv2 must be capable of generating this
trap, the snmpEnableAuthenTraps object
indicates whether this trap will be generated.
RMON Events (V2)
risingAlarm
1.3.6.1.2.1.16.0.1
The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates
an event that is configured for sending SNMP
traps.
fallingAlarm
1.3.6.1.2.1.16.0.2
The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates
an event that is configured for sending SNMP
traps.
Private Traps -
swPowerStatus
ChangeTrap
1.3.6.1.4.1.259.8.2.2.2.1.0.1
†
This trap is sent when the power state changes.
swFanFailureTrap
1.3.6.1.4.1.259.8.2.2.2.1.0.17
This trap is sent when the fan fails.
swFanRecoverTrap
1.3.6.1.4.1.259.8.2.2.2.1.0.18
This trap is sent when the fan failure has
recovered.
swIpFilterRejectTrap
1.3.6.1.4.1.259.8.2.2.2.1.0.40
This trap is sent when an incorrect IP address is
rejected by the IP Filter.
swSmtpConnFailure
Trap
1.3.6.1.4.1.259.8.2.2.2.1.0.41
This trap is triggered if the SMTP system cannot
open a connection to the mail server
successfully.
swMainBoardVer
MismatchNotificaiton
1.3.6.1.4.1.259.8.2.2.2.1.0.56
This trap is sent when the slave board version is
mismatched with the master board version. This
trap binds two objects, the first object indicates
the master version, whereas the second
represents the slave version.
swModuleVer
MismatchNotificaiton
1.3.6.1.4.1.259.8.2.2.2.1.0.57
This trap is sent when the slide-in module
version is mismatched with the main board
version.
swThermalRising
Notification
1.3.6.1.4.1.259.8.2.2.2.1.0.58
This trap is sent when the temperature exceeds
the switchThermalActionRisingThreshold.
Table 5-2 Supported Notification Messages (Continued)
Object Label
Object ID
Description