beautypg.com

Specification, Fig.2 – Sealey TA303 User Manual

Page 2

background image

TA303 Issue no: 2 - 20/12/11

Original Language Version

3. SPECIFICATION

Range

Resolution

Accuracy

400.0mV

0.1mV

± 0.5% of reading ± 3 digits

4.000V

1mV

40.00V

10mV

±1.5% of reading ± 2 digits

400.0V

100mV

600V

1V

± 1.8% of reading ± 2 digits

Range

Resolution

Accuracy

400.0mV

0.1mV

± 1.5% of reading ± 5 digits

4.000V

1mV

± 1.0% of reading ± 3 digits

40.00V

10mV

± 1.5% of reading ± 3 digits

400.0V

100mV

600V

1V

± 2.0% of reading ± 4 digits

DC Voltage (Auto ranging)

AC Voltage (Auto ranging)

Input Impedance: 10MΩ.

Maximum Input: 600Vdc.

Input Impedance: 10MΩ.

Frequency range: 50 to 60Hz.

Maximum Input: 600Vac rms.

Range

Resolution

Accuracy

4.000kHz

1Hz

40.00kHz

10Hz

± 1.5% of reading ± 3 digits

400.0kHz

100Hz

4.000MHz

1000Hz

40.00MHz

1kHz

± 2.0% of reading ± 4 digits

Frequency (Auto ranging)

Range

Resolution

Accuracy

0.5%~99.0%

0.1%

± 2.0% of reading ± 5 digits

Duty Cycle

Pulse Width: >100us, <100ms

Sensitivity: > 5V rms

Frequency width: 5Hz - 100kHz

Cylinder Range

Resolution Accuracy

4CYL

0~90.0°

5CYL

0~72.0° 0.1°

± 2.0% of reading ± 4 digits

6CYL

0~60.0°

8CYL

0~45.0°

Dwell Angle

Sensitivity: >5V rMS MIn up to 4.0000MHz range.

>15V rMS MIn on 40.00MHz range.

GENERAL INSTRUMENT SPECIFICATION

Instrument complies with

IEC 1010-1 En61010-1

Insulation

Class 2, Double Insulation

Overvoltage category

CAT.III 1000V / CAT.IV 600V

Display

4000 counts LCD display with

function indication

Polarity

Automatic, (-) negative polarity indication.

Over range

"OL" marks indication

Low battery indication

"BAT" is displayed when the battery

voltage drops below the operating level

Measurement rate

2 times per second, nominal

Auto power off

Analyser automatically shuts down after

approx. 30 minutes of inactivity

Operating environment

0ºC to 50ºC (32ºF to 122ºF) at < 70%

relative humidity.

Storage temperature

-20ºC to 60ºC (-4ºF to 140ºF) at < 80%

relative humidity.

For inside use, max height

2000m

Pollution degree

2

Power

One 9V battery (PP3)

Dimensions

170mm x 79mm x 50mm

Weight

366g

FUNCTION

RED TERMINAL

INPUT LIMIT

DC/AC Volts, Ohms, Continuity, Diode,

CAP., Type-K TEMP., Hz, % Duty,

Ms Dwell, rPM

VΩHz% etc.

600Volts AC DC

Current AC/DC 400mA

400mA

400mA DC/AC

Current AC/DC 20A

20A

*20A DC/AC

* 20 Amp measurement for 30 seconds maximum.

Ohms cannot be measured if voltage is present, ohms can be measured only in a non-powered circuit. However, the analyser is protected to 600 volts.

fig.2.