Figure 4-11: Jumper Selection for Option Board A9

CAUTION

Ensure that the jumper positions are correct. Running the motor
with signal settings that differ from the jumper positions will not
harm the inverter, but may harm the motor.

Note: If you change the AI/AO signal content, remember to change the corresponding board

parameter in Menu M7.

Jumper Block X1:

AI1 Mode

AI1 Mode: 0...20mA; Current Input

A B C D

A B C D

A B C D

AI1 Mode: Voltage Input; 0...10V

AI1 Mode: Voltage Input; 0...10V (Differential)

AI1 Mode: Voltage Input; -10...10V

A B C D

Jumper Block X6:

AO1 Mode

AI1 Mode: 0...20mA; Current Output

A B C D

A B C D

AO1 Mode: Voltage Output; 0...10V

= Factory Default

Jumper Block X2:

AI2 Mode

AI2 Mode: 0...20mA; Current Input

A B C D

A B C D

A B C D

AI2 Mode: Voltage Input; 0...10V

AI2 Mode: Voltage Input; 0...10V (Differential)

AI2 Mode: Voltage Input; -10...10V

CMB Connected to GND

A B C D

Jumper Block X3:

CMA and CMB Grounding

CMA Connected to GND

CMB Isolated from GND

CMA Isolated from GND

CMB and CMA
Internally Connected Together,
Isolated from GND