Magnum Energy MP Extension Box (MPX Series) User Manual
Page 9

2.0 Introduction
© 2011 Magnum Energy, Inc.
5
2.2 Available MPX Models
The three models in the MPX Series are: the MPXS-30D, MPXS-60S, and the MPXD-30D (see Figures 2-3
to 2-5). The MPXS-30D model is designed for use with a single MP enclosure (MPSL-30D and MPSH-
30D), the MPXS-60S is only used with the MPSL-60S, while the MPXD-30D is designed for use with
a dual MP enclosure (MPDH-30D). Each model comes in a left (L) and right (R) version. The ‘right’
version (MPXS-30D-R, MPXS-60S-R, or MPXD-30D-R) is used when the MPX is mounted to the right
of the MP enclosure, and the ‘left’ version (MPXS-30D-L, MPXS-60S-L, or MPXD-30D-L) is used when
the MPX is mounted to the left of the MP enclosure. The left version differs from the right only in that
the length of the supplied DC cables are different to accommodate the difference in distance from
the MP’s DC breaker to the new installed inverter.
Info: The MPXS-60S model is unique in that it provides #6 AC wiring and a single-pole
60 AAC breaker, rather than the #10 AC wiring and 30 AAC double-pole breaker that
comes with the MPXS-30D and MPXD-30D models.
TABLE 2-3, MPX MODELS
MPX
Model
Versions
(left or right installation)
Used With:
MP Enclosure
Inverters
MPXS-30D
MPXS-30D-L/MPXS-30D-R
MPSL-30D/MPSH-30D
MS4024PAE or MS4448PAE
stacked in parallel
MPXS-60S
MPXS-60S-L/MPXS-60S-R
MPSL-60S
MS4024 stacked in series
MPXD-30D
MPXD-30D-L/MPXD-30D-R
MPDH-30D
MS4024PAE or MS4448PAE
stacked in parallel
TABLE 2-2, DC 2/0 BATTERY CABLE LENGTHS
Model
Black Cable
Red Cable
MPXS-30D-L
23.25”
21.00”
MPXS-30D-R
15.25”
16.50”
MPXS-60S-L
23.25”
21.00”
MPXS-60S-R
15.25”
16.50”
MPXD-30D-L
39.00”
26.75”
MPXD-30D-R
14.75”
24.25”
MPSL-60S
MPXS-60S-L
MPSL-60S
MPXS-60S-R
OR
MPXS-60S on left side (MPXS-60S-L)
MPXS-60S on right side (MPXS-60S-R)
MS4024
I
NVERTER
MS4024
I
NVERTER
MS4024
I
NVERTER
MS4024
I
NVERTER
Figure 2-3, MPXS-60S Installation Confi gurations