3.0 Installation
© 2011 Magnum Energy, Inc.
23
AC OUTPUT
(from Master)
AC INPUT (to Master)
Master (MA)
Slave (SL1)
MPXS-30D
MPSL-30D Enclosure
Master Inverter AC
INPUT Breaker
Slave 1 Inverter AC
INPUT Breaker
AC INPUT (to Slave)
AC OUTPUT (from Slave)
Red
Black
Green
Red
Black
Black
Red
Green
Red
Black
White
Red w/ Stripe
Black w/ Stripe
White
Red w/ Stripe
Black w/ Stripe
MS-PAE Series Inverters
Router
RED w/STRIPE
BLACK w/STRIPE
WHITE
RED
BLACK
GREEN
WIRE
TO MPSL-30D
:
FROM INVERTER
:
AC INPUT
AC OUTPUT
AC OUTPUT
AC OUTPUT
AC INPUT
AC INPUT
INV HOT 2 OUT busbar
INV HOT 1 OUT busbar
AC NEUTRAL busbar
GROUND busbar
AC INPUT breaker
AC INPUT breaker
MA
SL1
Figure 3-18a, MPXS-30D / MPSL-30D Inverter AC Wiring