Magnum Energy MP Extension Box (MPX Series) User Manual
Page 12

3.0 Installation
© 2011 Magnum Energy, Inc.
8
Safe - Keep any fl ammable/combustible material (e.g., paper, cloth, plastic, etc.,) that may be
ignited by heat, sparks or fl ames at a minimum distance of 12 feet away from the MP/inverter
system. Do not install the MPX/MP/inverter system in any area that contains extremely fl ammable
liquids like gasoline or propane, or in locations that require ignition-protected devices. Sparks from
relays, circuit breakers, etc., could ignite the fumes or spills.
Accessible - Do not block access to the front of your system. Maintain at least a 36” (91 cm)
clear space in front to access the AC and DC wiring terminals and connections inside the MPX/MP
enclosure, as they will need to be checked and tightened periodically.
C
ONDUIT
K
NOCKOUTS
:
A = ½" and ¾" (x6)
B = ¾" and 1" (x6)
C = 1½" and 2" (x4)
C
C
TOP VIEW
8
15/64"
8
1/16"
A
LEFT SIDE VIEW
8
1/16"
A
RIGHT SIDE VIEW
8
15/64"
B
B
B
BOTTOM VIEW
8
15/64"
8
1/16"
FRONT VIEW
7
15/64"
16"
C
C
C
C
A
A
A
A
B
B
B
0.8145"
0.412"
KEYHOLE DETAIL
(x4)
0.525"
8"
0.2
4"
2"
1
1/8
1
1
14"
BACK VIEW
B
B
B
A
A
B
B
B
Figure 3-1, MPX Series Dimensions and Knockout Locations/Sizes
Removing the MPX’s Front Cover
Remove the front cover on the MPX extension using a T25 Torx screwdriver. The screws are #10-32
x 3/8” Pan head, T25 Torx drive, thread cutting screws and the washers are #10 external tooth Star
washers. You will need to reattach the MPX cover once all wiring is completed and tested.