beautypg.com

Yaskawa SmartTrac AC1 User Manual

Page 38

background image


SMART TRAC AC1

4-18

••

Smart Trac AC1 Installation Technical Manual TM 3554-000

Rated Voltage

400.0 VAC

11. Set the correct Nameplate voltage of the motor, using the

and

keys to scroll and the

key to move one decimal point to

the right.

Rated Voltage

460.0 VAC

12. Press

to store the value in memory. The message "Entry

Accepted" will appear briefly, followed by a return to the previous
"Rated Voltage" message.

Entry Accepted

Rated Voltage

400.0 VAC

13. Enter the current and the rest of the parameters following a similar

procedure to that of the motor nameplate voltage.

14. When all of the parameters are entered, execute Auto-Tuning:

15. Press the

. The message "Tuning Ready?" will appear.

Tuning Ready?
Press RUN key

16. Press

. The drive will first output current to the motor, then run

the motor at a high speed. During tuning, the following message will
appear.

Tune proceeding

XX Hz X.XX A

If no problems are encountered., the following message will
appear:

Tune Successful

If a problem occurs during Auto-Tuning execution, the "Tune
Aborted" message appears with a reason listed. See "Auto-Tuning
Faults and Corrective Actions".

Tune Aborted

"Reason"

17. If successful, record the settings for parameters E2-01 to E2-09. You

use the Programming Menu (see "Checking Motor Parameters").

18. Remove power from the Smart Trac AC1. Wait until the CHARGE

light goes out.