beautypg.com

Yaskawa YASNAC PC NC Maintenance Manual User Manual

Page 166

background image

The VS-626M5

PC NC Maintenance Manual

4-145

To return to operation mode using a regular external run com-
mand, change the lower 2 bits of C1-37 from “ ” to “ .”

(6)

Fault Display Mode

If a protective function is activated because of a fault, the fault
code is displayed. Up to six faults are recorded, and may be
viewed to determine the order of a series of faults.

Notes on resetting faults

To reset a fault by the digital operator after removing the cause,
depress the RESET key in the fault display mode. In other
modes, the RESET key cannot reset the fault.

Before resetting, turn OFF the run command signals (FWD, REV,
ORT) that are input externally.

Time

Fault Reset

01 occurred

(Overcurrent)

31 occurred

(Motor Overspeed)

d2 occurred

(CPU built-in A/D error)

Display Example

EDisplays the first fault No.

EDisplays the second fault No.

EDisplays the third fault No.