The following table summarizes the output current ratings for the V1000 and V7 with respect to the specific drive model.
Please note that the V7 current rating is based on a “Heavy Duty” rating, whereas, the V1000 factory default is based on a
“Normal Duty” rating. See below for an explanation of the differences between “Heavy” and “Normal” duty ratings.
Note: If the V1000 drive is set to “Heavy Duty”, the current ratings are the same as the V7 drive. <1>
Rated
Input Voltage
V7 Drive Model
Number
CIMR-V7AM
Heavy Duty
Drive Model
Number
CIMR-V
Normal Duty
Rated Output
Current (Amps)
Nominal HP
Rated Output
Current (Amps)
Nominal HP
200V,
1-Phase
B0P11
B0P21
0.8
1.6
1/8
1/4
BA0001
BA0002
1.2
1.9
1/8 & 1/4
1/4
B0P41
B0P71
3.0
5.0
1/2
3/4 & 1
BA0003
BA0006
3.3
6.0
1/2 & 3/4
1
B1P51
B2P21
8.0
11.0
2
3
BA0010
BA0012
9.6
12.0
2 & 3
3
B3P71
17.5
5
BA0018 <1>
19.6
5
200V,
3-Phase
20P11
20P21
20P41
0.8
1.6
3.0
1/8
1/4
1/2
2A0001
2A0002
2A0004
1.2
1.9
3.5
1/8 & 1/4
1/4
1/2 & 3/4
20P71
21P51
5.0
8.0
3/4 & 1
2
2A0006
2A0010
6.0
9.6
1
2 & 3
22P21
23P71
11.0
17.5
3
5
2A0012
2A0020
12.0
19.6
3
5
25P51
27P51
25.0
33.0
7.5
10
2A0030
2A0040
30.0
40.0
7.5 & 10
10
N/A
N/A
N/A
N/A
N/A
N/A
2A0056
2A0069
56.0
69.0
20
25
400V,
3-Phase
40P21
40P41
1.2
1.8
1/2
3/4
4A0001
4A0002
1.2
2.1
1/2
3/4 & 1
40P71
41P51
3.4
4.8
1 & 2
3
4A0004
4A0005
4.1
5.4
2
3
42P21
43P71
45P51
5.5
8.6
14.8
3
5
7.5 & 10
4A0007
4A0009
4A0011
6.9
8.8
11.1
4
5
7.5
45P51
47P51
14.8
18.8
7.5 & 10
10
4A0018
4A0023
18.0
24.0
10
15
N/A
N/A
N/A
N/A
N/A
N/A
4A0031
4A0038
31.0
38.0
20
25