Yaskawa VS606 V7 to V1000 User Manual
Page 20

Product Transition Guide
PL. V1000.01 Rev: 4/1/09
PL.V1000.01 Transition Guide 4/1/09
Page 20 of 38
Yaskawa Electric America, Inc.
Acceleration /
deceleration time
resolution selection
n018
0
C1-10
1
V7
V1000
n018
→0
C1-10
→1
n018
→1
C1-10
→0
Acceleration time 1
n019
10.0
sec
C1-01
10.0
sec
Deceleration time 1
n020
10.0
sec
C1-02
10.0
sec
Acceleration time 2
n021
10.0
sec
C1-03
10.0
sec
Deceleration time 2
n022
10.0
sec
C1-04
10.0
sec
S-curve at accel. Start
n023
0 (0 sec)
C2-01
0.2 sec
In the V7 one of four values could be
selected for all s-curves. The V1000
requires a separate time setting for each
s-curve.
S-curve at accel. End
n023
0 (0 sec)
C2-02
0.2 sec
S-curve at decel. start
n023
0 (0 sec)
C2-03
0.2 sec
S-curve at decel. end
n023
0 (0 sec)
C2-04
0.2 sec
Multi speed reference 1
n024
6.00 Hz
d1-01
o2-09,
FMAX
dep.
Multi speed reference 2
n025
0.00 Hz
d1-02
0 Hz
Multi speed reference 3
n026
0.00 Hz
d1-03
0 Hz
Multi speed reference 4
n027
0.00 Hz
d1-04
0 Hz
Multi speed reference 5
n028
0.00 Hz
d1-05
0 Hz
Multi speed reference 6
n029
0.00 Hz
d1-06
0 Hz
Multi speed reference 7
n030
0.00 Hz
d1-07
0 Hz
Multi speed reference 8
n031
0.00 Hz
d1-08
0 Hz
Jog frequency
n032
6.00 Hz
d1-17
6.00 Hz
Frequency reference
upper limit
n033
100%
d2-01
100.0%
Frequency reference
lower limit
n034
0%
d2-02
0.0%
Digital operator display
unit for frequency
reference values.
n035
0
o1-03
0
V7
V1000
n035
→0
o1-03
→0
n035
→1
o1-03
→1
n035
→2~39
o1-03
→2 and set
E2-04, E4-04,
E4-05
n035
→40~3999
o1-03
→3 and set
o1-10, o1-11
Motor rated current
n036
E2-01
kVA
dep.
Depends on the drive capacity
(V7,V1000)
Motor overload
protection
n037
0
L1-01
1
V7
V1000
n037
→0
L1-01
→1
n037
→1
L1-01
→2~4
n037
→2
L1-01
→0
Motor overload
protection time
n038
8 min
L1-02
1 min
Needs not to be changed.
Drive
Parameter
Function
V7
V1000
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value