beautypg.com

Yaskawa VS606 V7 to V1000 User Manual

Page 20

background image

Product Transition Guide

PL. V1000.01 Rev: 4/1/09

PL.V1000.01 Transition Guide 4/1/09
Page 20 of 38
Yaskawa Electric America, Inc.

Acceleration /

deceleration time

resolution selection

n018

0

C1-10

1

V7

V1000

n018

→0

C1-10

→1

n018

→1

C1-10

→0

Acceleration time 1

n019

10.0

sec

C1-01

10.0

sec

Deceleration time 1

n020

10.0

sec

C1-02

10.0

sec

Acceleration time 2

n021

10.0

sec

C1-03

10.0

sec

Deceleration time 2

n022

10.0

sec

C1-04

10.0

sec

S-curve at accel. Start

n023

0 (0 sec)

C2-01

0.2 sec

In the V7 one of four values could be

selected for all s-curves. The V1000

requires a separate time setting for each

s-curve.

S-curve at accel. End

n023

0 (0 sec)

C2-02

0.2 sec

S-curve at decel. start

n023

0 (0 sec)

C2-03

0.2 sec

S-curve at decel. end

n023

0 (0 sec)

C2-04

0.2 sec

Multi speed reference 1

n024

6.00 Hz

d1-01

o2-09,

FMAX

dep.

Multi speed reference 2

n025

0.00 Hz

d1-02

0 Hz

Multi speed reference 3

n026

0.00 Hz

d1-03

0 Hz

Multi speed reference 4

n027

0.00 Hz

d1-04

0 Hz

Multi speed reference 5

n028

0.00 Hz

d1-05

0 Hz

Multi speed reference 6

n029

0.00 Hz

d1-06

0 Hz

Multi speed reference 7

n030

0.00 Hz

d1-07

0 Hz

Multi speed reference 8

n031

0.00 Hz

d1-08

0 Hz

Jog frequency

n032

6.00 Hz

d1-17

6.00 Hz

Frequency reference

upper limit

n033

100%

d2-01

100.0%

Frequency reference

lower limit

n034

0%

d2-02

0.0%

Digital operator display

unit for frequency

reference values.

n035

0

o1-03

0

V7

V1000

n035

→0

o1-03

→0

n035

→1

o1-03

→1

n035

→2~39

o1-03

→2 and set

E2-04, E4-04,

E4-05

n035

→40~3999

o1-03

→3 and set

o1-10, o1-11

Motor rated current

n036

E2-01

kVA

dep.

Depends on the drive capacity

(V7,V1000)

Motor overload

protection

n037

0

L1-01

1

V7

V1000

n037

→0

L1-01

→1

n037

→1

L1-01

→2~4

n037

→2

L1-01

→0

Motor overload

protection time

n038

8 min

L1-02

1 min

Needs not to be changed.

Drive

Parameter

Function

V7

V1000

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value