Parameter correspondence table, V7 and v1000 differences in parameter settings, 6 parameter correspondence table – Yaskawa VS606 V7 to V1000 User Manual
Page 18

Product Transition Guide
PL. V1000.01 Rev: 4/1/09
PL.V1000.01 Transition Guide 4/1/09
Page 18 of 38
Yaskawa Electric America, Inc.
1.6 Parameter Correspondence Table
V7 and V1000 Differences in Parameter Settings
The list in Section 1.6 shows the parameter relations between the V7 and the V1000. It lists the parameters and setting values
necessary for V7 replacement by a V1000, but does not show the complete V1000 parameters and extended parameter setting
ranges. For details about new functions, parameters and parameter settings refer to the instruction manual
V7
→V1000 Parameter Correspondence for Drive Replacement
Drive
Parameter
Function
V7
V1000
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value
Parameter access level
n001
1
A1-01
2
V7
V1000
n001
→0
A1-01
→0
Initialization
A1-03
0
n001
→1~4
A1-01
→2
n001
→5
A1-01
→2
b1-08
→1
RUN cmd. In PRG mode
sel.
b1-08
0
n001
→6
o4-11
→1
Initialize mode (Spec.)
o2-09
0
n001
→10
A1-03
→2220
n001
→11
A1-03
→3330
Control mode selection
n002
0
A1-02
0
V7
V1000
n002
→0
A1-02
→0
n002
→1
A1-02
→2
RUN command source
selection
n003
0
b1-02
1
V7
V1000
n003
→0
b1-02
→0
n003
→1
b1-02
→1
n003
→2
b1-02
→2
n003
→3
b1-02
→3
Frequency reference
source selection
n004
0
b1-01
1
V7
V1000
n004
→0
— (no operator pot i)
n004
→1
b1-01
→0
n004
→2
b1-01
→1 and
(H3-01
→0 (term. A1) or
H3-09
→0 (term. A2))
n004
→3
b1-01
→1 and H3-09→2
(term. A2)
n004
→4
b1-01
→1 and H3-09→3
(term. A2)
n004
→5
b1-01
→4
Frequency reference by
analog input A2 (signal
level) selection
n004
n078
0
1
H3-09
2
n004
→6
b1-01
→2
n004
→7
n078
→0
b1-01
→1 and
(H3-01
→0 (term. A1)
or
H3-09
→0 (term. A2))
n004
→8
n078
→1
b1-01
→1 and H3-09→2
(term. A2)
n004
→9
b1-01
→3