beautypg.com

Yaskawa VS606 V7 to V1000 User Manual

Page 5

background image

PL.V1000.01 Transition Guide 4/1/09

Page 5 of 38

Yaskawa Electric America, Inc.

Product Transition Guide

PL. V1000.01 Rev: 4/1/09

Options,
Others

Option
Cards

< Is an option card installed? >

• Check if any option card is installed.

– If an option card is installed, get the equivalent option card for the V1000.
– Never attempt to apply V7 option cards to the V1000 unit.
– The option card on the V1000 may have another connector on the V7. Make sure that

the connectors fit into the new option card before using it.

Others

< Is a braking resistor installed? >

• Check if a braking resistor is installed on the current drive.

– Check the braking resistor before connecting it to the new drive.
– Connect the braking resistor to the equivalent terminals on the new unit.
– If it is a heatsink installed braking resistor (ERF-type), it will not fit in the drive and

will need to be panel mounted.

– The terminals might have a different location in the new drive; check to ensure that

existing wiring is long enough to reach the new terminal location. <1>

< Is a braking unit installed? >

• Check if a braking unit is used in the current installation.

– Check the braking unit before connecting it to the new drive.
– Connect the braking unit to the equivalent terminals on the new unit.
– The terminals might have a different location in the new drive; check to ensure that

existing wiring is long enough to reach the new terminal location. <1>

< Is an AC reactor or DC choke installed? >

• Check if an AC reactor or DC choke is used in the current installation.

– Check the reactor or choke before connecting it to the new drive.
– Make sure that the reactor or choke data are appropriate for the replacement drive.
– The terminals might have a different location in the new drive; check to ensure that

existing wiring is long enough to reach the new terminal location. <1>

• Refer to the instruction manual for questions about installation, parameter settings or detailed parameter/function descriptions.
• In case of technical questions regarding replacement, please contact your Yaskawa representative. <1>

Item

Checkpoints

Checked?