Yaskawa VS606 V7 to V1000 User Manual
Page 24

Product Transition Guide
PL. V1000.01 Rev: 4/1/09
PL.V1000.01 Transition Guide 4/1/09
Page 24 of 38
Yaskawa Electric America, Inc.
Analog input signal level
selection (CN2
→
Terminal A2)
n078
0
H3-09
1
V7
V1000
n078
→0
H3-09
→0
n078
→1
H3-09
→2
Frequency reference bias
max. value for terminal
CN2 reference input
→
terminal A2
n079
10%
-
-
This function can not be used with
current input in the V1000.
For voltage input at terminal A2 the
following has to be set:
H3-09
→1
H3-10
→0
H3-11
→n079
H3-11
→-n079
Carrier frequency
selection
n080
4
C6-02
o2-04
dep.
V7
V1000
Carrier frequency upper
limit
C6-03
C6-02
dep.
n080
→1
C6-02
→1 (2kHz)
Carrier frequency lower
limit
C6-04
C6-02
dep.
n080
→2
C6-02
→2 (5kHz)
Carrier frequency
proportional gain
C6-05
0
n080
→3
C6-02
→3 (8kHz)
n080
→4
C6-02
→4 (10kHz)
n080
→7~9
C6-03/04/05 must
be used
Momentary power loss
detection selection
n081
0
L2-01
0
V7
V1000
n081
→0
L2-01
→0
n081
→1
L2-01
→1
n081
→2
L2-01
→2
Automatic restart
attempts
n082
0
L5-01
0
Jump frequency 1
n083
0.0 Hz
d3-01
0.0 Hz
Jump frequency 2
n084
0.0 Hz
d3-02
0.0 Hz
Jump frequency 3
n085
0.0 Hz
d3-03
0.0 Hz
Jump frequency
bandwidth
n086
0.0 Hz
d3-04
1.0 Hz
Operation time counter
selection
n087
0
o4-02
0
V7
V1000
n087
→0
o4-02
→0
n087
→1
o4-02
→1
Accumulated operation
time
n088
0 H
o4-01
0 H
DC injection braking
current
n089
50%
b2-02
50%
DC injection time at stop
n090
0.5 sec
b2-04
o2-09
dep.
DC injection time at start
n091
0 sec
b2-03
0 sec
Stall prevention during
deceleration
n092
0
L3-04
1
V7
V1000
n092
→0
L3-04
→1
n092
→1
L3-04
→0, 3
Stall prevention level
during acceleration
n093
170%
L3-02
150%
Stall prevention level
during run
n094
160%
L3-06
160%
Drive
Parameter
Function
V7
V1000
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value