Yaskawa GPD 515/G5 to G7 User Manual
Page 36

Product Transition Guide
GPD515/G5 to G7
GPD515/G5 Parameters
G7 Parameters
Parameter
No.
Name
(DigitalOperator
Display)
Setting or Selection
Parameter
No.
Name
(Digital Operator Display)
Remarks on
Setting or Selection
O1-05
Parameter No.
Display Selection
Address Display
0:Parameter Number
1:Memobus Address
o1-05
LCD Brightness
Adjustment
Modified function:
Sets the contrast of the digital
operator LCD. A set ting of
“1” is the lightest contrast and
a setting of “5” is the darkest
contrast.
—
—
—
o2-10
Cumulative CoolingFan
Operation Time Setting
New parameter
—
—
—
o2-12
Fault Trace/Fault
History Clear Function
New parameter
0: Disabled no effect.
1: Enabled - resets U2 and U3
monitors, and returns o2-12 to
zero.
—
—
—
o2-14
kWh User Monitor
Initialization
New parameter
0: Disabled no change.
1: Enabled - Resets U1-29 to
zero and returns o2-14 to zero.
—
—
—
o3-01
Copy Function
Selection
New parameter
0: COPY SELECT no
function
1: INV -> OP READ - All
parameters are copied from
the Drive to the digital
operator.
2: OP -> INV WRITE - All
parameters are copied from
the digital operator to the
Drive.
3: OP<-->INV VERIFY -
Parameter settings in the Drive
are compared to those in the
digital operator.
NOTE: When using the copy
function, the Drive model
number o2-04, software
number U1-14, and control
method A1-02 must match or
an error will occur.
—
—
—
o3-02
Copy Allowed
Selection
Read Allowable
New parameter
0: Disabled - No digital
operator copy functions are
allowed.
1: Enabled - Copying allowed
PL.G7.02.TransitionGuide 4/21/04
Page 36 of 38
Yaskawa Electric America, Inc