Yaskawa GPD 515/G5 to G7 User Manual
Page 26

Product Transition Guide
GPD515/G5 to G7
PL.G7.02.TransitionGuide 4/21/04
Page 26 of 38
Yaskawa Electric America, Inc
GPD515/G5 Parameters
G7 Parameters
Parameter
No.
Name
(Digital Operator Display)
Setting or Selection
Parameter
No.
Name
(Digital Operator Display)
Remarks on
Setting or Selection
—
— —
d6-03
Magnetic Field Forcing
Function Selection
New Parameter
0:Disabled
1:Enabled
E1-02
Motor Selection
0:Std Fan-Cooled
1:Std Blower-Cooled
2:Vector Motor
L1-01
Motor Overload Protection
Selection
Changed Parameter No.
Additional selection
0: Disabled
1: Standard Fan Cooled
2: Standard Blower Cooled
3: Vector Motor
—
E2-11
Motor Rated Output
New Parameter
This value is automatically set during auto
tuning.
E3-01 Motor 2 Control Method
Selection
0: V/F control
1: V/F with PG Feedback
2: Open Loop Vector
3: Flux Vector
E3-01
Motor 2 Control Method
Selection
Additional selection
4: Open Loop Vector Control 2
E4-01 Motor 2 Max. Output
Frequency
—
E3-02
Motor 2 Maximum Output
Frequency
Changed Parameter No.
E4-02 Motor 2 Max.Voltage
—
E3-03
Motor 2 Maximum Output
Voltage
Changed Parameter No.
E4-03 Motor 2 Max.
Voltage Frequency
Base Frequency
—
E3-04
Motor 2 Base Frequency
Base Frequency
Changed Parameter No.
E4-04 Motor 2 Mid.
Output Frequency 1
Mid Frequency
—
E3-05
Motor 2 Mid Output
Frequency
Mid Frequency
Changed Parameter No.
E4-05 Motor 2 Mid.
Output Frequency
Voltage 1
Mid Voltage
—
E3-06
Motor 2 Mid Output
Voltage VA
Mid Voltage
Changed Parameter No.
E4-06 Motor 2 Min.
Output Frequency
Min Frequency
—
E3-07
Motor 2 Minimum Output
Frequency
Min Frequency
Changed Parameter No.
E4-07 Motor 2 Min.
Output Frequency
Voltage
Min Voltage
—
E3-08
Motor 2 Minimum Output
Voltage
Min Voltage
Changed Parameter No.
E5-01 Motor 2 Rated Current
—
E4-01
Motor 2 Rated Current
Changed Parameter No.
E5-02 Motor 2 Rated Slip
—
E4-02
Motor 2 Rated Slip
Changed Parameter No.
E5-03 Motor 2
No-load Current
—
E4-03
Motor 2 No-Load Current Changed Parameter No.
E5-04 Motor 2
Number of poles
—
E4-04
Motor 2 Number of Poles Changed Parameter No.
E5-05 Motor 2 Line-to-line
Resistance
—
E4-05
Motor 2 Line-to-Line
Resistance
Changed Parameter No.
E5-06 Motor 2 Leak Inductance
—
E4-06
Motor 2 Leakage
Inductance
Changed Parameter No.
—
— —
E4-07
Motor 2 Rated Output
New Parameter
This value is automatically set during auto-
tuning.
—
— —
F4-07
AO-12 Channel 1 Signal
Level
New Parameter
Sets the range of the voltage output.
0: 0 to 10 Vdc
1: -10 to +10 Vdc
—
— —
F4-08
AO-12 Channel 2 Signal
Level
New Parameter
Sets the range of the voltage output.
0: 0 to 10 Vdc
1: -10 to +10 Vdc