I/o terminal cross reference g5 to g7 – Yaskawa GPD 515/G5 to G7 User Manual
Page 13

Product Transition Guide
GPD515/G5 to G7
__________________________
I/O Terminal Cross Reference G5 to G7
GPD515/G5 Terminal
G7 Terminal
Type
GPD515/G5
Terminal
Default Function
G7
Terminal
Default Function
G7 Description
9 M1
10
During run (NO contact)
Form A dry contact
250VAC1A
30VDC, 1A
M2
During run
(N.O. contact)
Multi-function digital output
Form A dry contact
250VAC, 1A
30VDC, 1A
Function set by H2-01
25
Zero speed detection
Open collector output, 48V, 50mA
P3
Factory setting:
Drive ready
Multi-function open collector
output
48VDC, 50mA
Function set by H2-04
27
Open collector output common
C3
Open collector output common
26
Speed agree detection
Open collector output
48V, 50mA or less
P4
Factory setting:
Fout detect 2
Multi-function open collector
output
48VDC, 50mA
Function set by H2-05
27
Open collector output common
C4
Open collector output common
18 MA
19 MB
Digital Output Signals
20
Dedicated fault contact
Form C dry contact
250VAC, 1A
30VDC, 1A
MC
Fault contact output
Dedicated fault contact
Form C dry contact:
250VAC, 1A
30VDC, 1A
M3
~
~
M4
Zero speed
(N.O. contact)
Multi-function digital output
Form A dry contact
250VAC, 1A
30VDC, 1A
Function set by H2-02.
M5
~
~
M6
Frequency agree
(N.O. contact)
Multi-function digital output
Form A dry contact
250VAC, 1A
30VDC, 1A
Function set by H2-03
21
Frequency monitor
10VDC=100% output frequency
(2mA maximum)
FM
Output frequency
0 to +10VDC or 0 to ±10VDC
(Max current 2mA) (500ohm)
10VDC or 20mA=100% output
frequency
Function set by H4-01
23
Current monitor
5VDC=drive rated current
(2mA maximum)
AM
Output current
0 to +10VDC or 0 to ±10VDC
(2mA maximum) (500ohm)
5VDC or 12mA=100% drive
rated current
Function set by H4-04
Analog Output Signals
22
Common (Current Monitor)
AC
Analog common
–
PL.G7.02.TransitionGuide 4/21/04