Yaskawa GPD 515/G5 to G7 User Manual
Page 25

Product Transition Guide
Appendix 2- Parameter Differences
____________________________
PL.G7.02.TransitionGuide 4/21/04
Page 25 of 38
Yaskawa Electric America, Inc
GPD515/G5 Parameters
G7 Parameters
Parameter
No.
Name
(Digital Operator Display)
Setting or Selection
Parameter
No.
Name
(Digital Operator Display)
Remarks on
Setting or Selection
—
— —
C6-02
Carrier Frequency
Selection
New parameter function different than old
C6-02 in GPD515/G5
0: Low noise
1: Fc = 2.0 kHz
2: Fc = 5.0 kHz
3: Fc = 8.0 kHz
4: Fc = 10.0 kHz
5: Fc = 12.5 kHz
6: Fc = 15.0 kHz
F: Program Determined by the settings of C6-
03 thru C6-05
C6-01 Carrier Frequency Upper
Limit
—
C6-03
Carrier Frequency
Upper Limit
Changed Parameter No.
C6-02 Carrier Frequency Lower
Limit
—
C6-04
Carrier Frequency
Lower Limit
Changed Parameter No.
C6-03 Carrier Frequency
Proportional Gain
—
C6-05
Carrier Frequency
Proportional Gain
Changed Parameter No.
New Parameter
—
— —
C6-11
Carrier Frequency
Selection Open Loop
Vector Control 2
Select the carrier frequency when open loop
vector control 2 is used.
1: 2 kHz
2: 4 kHz
3: 6 kHz
4: 8 kHz
C7-01 Hunting Prevention
Selection
0:Disabled
1:Enabled
n1-01
Hunting Prevention
Selection
Changed Parameter No.
C7-02 Hunting Prevention Gain
—
n1-02
Hunting Prevention Gain
Setting
Changed Parameter No.
C8-08 AFR Gain
—
n2-01
Speed Feedback Detection
Control AFR Gain
Changed Parameter No.
C8-09 AFR Time Constant
—
n2-02
AFR Time
Changed Parameter No.
—
— —
n2-03
Speed Feedback Detection
Control
AFR Time Constant 2
New parameter
Sets the time constant to control the amount
of change in the speed at low speed.
—
— —
d1-09
Frequency Reference 9
New Parameter
—
— —
d1-10
Frequency Reference 10
New Parameter
—
— —
d1-11
Frequency Reference 11
New Parameter
—
— —
d1-12
Frequency Reference 12
New Parameter
—
— —
d1-13
Frequency Reference 13
New Parameter
—
— —
d1-14
Frequency Reference 14
New Parameter
—
— —
d1-15
Frequency Reference 15
New Parameter
—
— —
d1-16
Frequency Reference 16
New Parameter
D1-09 Jog Frequency Reference
d1-17
Jog Frequency Reference Changed Parameter No.
—
— —
d2-03
Master Speed Reference
Lower Limit
New Parameter
—
— —
d6-01
Magnetic Field Weakening
Level
New Parameter
—
— —
d6-02
Magnetic Field Frequency New Parameter