• Tune-No Rotate 1
Sets parameters related to motor characteristics without rotating the motor. Perform Tune-
No Rotate if the load cannot be disconnected from the motor for tuning purposes. 
• Term
Resistance
Adjusts parameter settings for the resistance between motor lines. Sends current into the 
motor coils without rotating the motor. For use when the cable between the drive and motor 
exceeds 50 m, or when the length of the motor cable has changed after proper Auto-Tuning 
has already been performed. Also useful for minimizing differences when the motor or drive 
capacity changes. 
• Parameter
Calculations
Parameter calculations require that motor-related data be entered either directly from the 
motor nameplate or from the motor test report. Frequency-related values must be entered in 
hertz. If online, only parameter calculations may be selected. 
• Tune-No Rotate 2
The same as Tune-No Rotate 1. Perform this type of Auto-Tuning on a second motor if 
used (motor 2). 
• PM
Parameter
PM Motor Parameter Tuning requires that motor-related information from the motor's 
nameplate or from the test report be entered. 
• Z
Pulse
Z Pulse Offset Tuning calculates the Z pulse offset (
Δθ) if the PG encoder has been