Option LED Display
The MECHATROLINK-III Option has four LEDs that indicate the option card or communication status.
Checking LED Operation
Table 4 Option LED States
Name
Display
Operating Status
Remarks
R/E
Lit in
green
Power supply on
• SI-ET3 has been successfully powered up
• An internal, self-diagnostic check completed in the SI-ET3
Lit in red Error
• Error/alarm occured
• Command error occurred (parameter error, phase error, combination error)
Flashing in
red
SI-ET3 error
Error found during SI-ET3’s self-diagnostic check
Unlit
Power supply off
• The drive has no power
• SI-ET3 is not properly connected to the drive, or SI-ET3 has no power
• An internal, self-diagnostic error occurred in the SI-ET3
CON
Lit in
green
Connection established
Established connection
Unlit
Connection unestablished
Connection with master device is not established
LK1
Lit in
green
Connector CN1 connected
Connector CN1 is connected to other stations
Unlit
Connector CN1
disconnected
Connector CN1 is not connected to other stations (cable not connected, cable
disconnected, other stations not powered up)
LK2
Lit in
green
Connector CN2 connected
Connector CN2 is connected to other stations
Unlit
Connector CN2
disconnected
Connector CN2 is not connected to other stations (cable not connected, cable
disconnected, other stations not powered up)