beautypg.com

Option led display, For details on the, Checking led operation – Yaskawa SI-ET3 User Manual

Page 9

background image

4 Option Components

YASKAWA ELECTRIC SIEP C730600 62B 1000-Series Option SI-ET3 Technical Manual

9

‹

Option LED Display

The MECHATROLINK-III Option has four LEDs that indicate the option card or communication status.

„

Checking LED Operation

Table 4 Option LED States

Name

Display

Operating Status

Remarks

R/E

Lit in
green

Power supply on

• SI-ET3 has been successfully powered up
• An internal, self-diagnostic check completed in the SI-ET3

Lit in red Error

• Error/alarm occured
• Command error occurred (parameter error, phase error, combination error)

Flashing in

red

SI-ET3 error

Error found during SI-ET3’s self-diagnostic check

Unlit

Power supply off

• The drive has no power
• SI-ET3 is not properly connected to the drive, or SI-ET3 has no power
• An internal, self-diagnostic error occurred in the SI-ET3

CON

Lit in
green

Connection established

Established connection

Unlit

Connection unestablished

Connection with master device is not established

LK1

Lit in
green

Connector CN1 connected

Connector CN1 is connected to other stations

Unlit

Connector CN1
disconnected

Connector CN1 is not connected to other stations (cable not connected, cable
disconnected, other stations not powered up)

LK2

Lit in
green

Connector CN2 connected

Connector CN2 is connected to other stations

Unlit

Connector CN2
disconnected

Connector CN2 is not connected to other stations (cable not connected, cable
disconnected, other stations not powered up)