Invcmd_stat, Invcmd_io response – Yaskawa SI-ET3 User Manual
Page 38
9 Main Command
38
YASKAWA ELECTRIC SIEP C730600 62B 1000-Series Option SI-ET3 Technical Manual
INVCMD_STAT
INVCMD_IO Response
Vender Specific
bit 1
bit 0
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
oPE Error
Drive Ready
Speed Agree
Zero Servo
Main Power
Supply ON
Basblock
Released
Reverse
Operation
Forward
Operation
Vender Specific
bit 9
bit 8
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
Not used
Zero Servo
Motor 2
Selection
LOCAL/
REMOTE
Power Loss
Recovery/
Momentary
Power Loss
Recovery
Fault reset Signal
Input
Reserved (0)
Vender Specific
bit 23
bit 22
bit 21
bit 20
bit 19
bit 18
bit 17
bit 16
Not used
bit 31
bit 30
bit 29
bit 28
bit 27
bit 26
bit 25
bit 24
Reserved (0)
SEL_MON2
Status
SEL_MON1
Status
Bit
Name
Description
0
Forward Operation
0: Stop
1: Forward operation in progress
1
Reverse Operation
0: Stop
1: Reverse operation in progress
2
Baseblock Released
0: Baseblock
1: Baseblock released
3
Main Power Supply ON
0: Main power supply OFF
1: Main power supply ON
4
Zero speed
1: Zero Speed
5
Speed Agree
1: Speed agree
6
Drive Ready
1: Drive ready
7
oPE Error
1: oPE error
9
Fault Reset Signal being Input
1: Fault reset signal being input
10
Power Loss Recovery/
Momentary Power Loss Recovery
0: Power loss recovery
1: Momentary power loss recovery
11
LOCAL/REMOTE
0: LOCAL
1: REMOTE
12
Motor 2 Selection
0: Motor 1
1: Motor 2
13
Zero Servo
1: Zero servo
24
SEL_MON1 Status
0: Disabled
1: SEL_MON1 enabled
25
SEL_MON2 Status
0: Disabled
1: SEL_MON2 enabled
Vender Specific
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Not used
Vender Specific
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
Not used
Vender Specific
bit 23
bit 22
bit 21
bit 20
bit 19
bit 18
bit 17
bit 16
Not used
bit 31
bit 30
bit 29
bit 28
Vender Specific
bit 27
bit 26
bit 25
bit 24
Reserved (0)