beautypg.com

9 troubleshooting, 1 blink codes, Troubleshooting – SMA SMC 4600A Installation User Manual

Page 58: Blink codes

background image

Troubleshooting

SMA Solar Technology AG

58

SMC46-60A11-IA-en-81

Installation Manual

9 Troubleshooting

If the inverter displays blink codes or error messages which differ from those described below, contact
the SMA Service Line.
You will find a description of display messages during operation, status messages and measurement
channels in the user manual provided.
Do not perform any repairs that are not described here and take advantage of the 24-hour
replacement service (inverter ready for shipping and handed over to a freight-forwarding company
within 24 hours) and the SMA Solar Technology AG repair service instead.

9.1 Blink Codes

Green

Red

Yellow

Status

Flashing

flashing

flashing

OK (start-up phase)

Permanently glowing

is not glowing

is not glowing

OK (feed-in operation)

permanently glowing

is not glowing

Earth fault or varistor
defective

permanently glowing

OK (initialisation)

Is flashing quickly
(3 x per second)

is not glowing

is not glowing

OK (stop)

permanently glowing

is not glowing

Earth fault or varistor
defective

Is flashing slowly
(1 x per second)

is not glowing

is not glowing

OK (waiting, grid
monitoring)

Goes out briefly
(approx. 1 x per
second)

permanently glowing

is not glowing

Earth fault or varistor
defective

is not glowing

is not glowing

OK (derating)

Is not glowing

is not glowing

is not glowing

OK (night-time
deactivation or
Electronic Solar Switch
not connected)

is glowing / flashing

Disturbance

permanently glowing

is not glowing

Earth fault or varistor
defective

is glowing / flashing

Earth fault or varistor
defective and
disturbance