4. Check the strings for earth faults as described in Section 9.3.1 "Checking the PV Array for Earth
5. Connect the assembled DC connectors to the inverter.
☑ The DC connectors click audibly into place.
6. In order to seal the inverter, all unused DC inputs must be closed using DC connectors and
sealing plugs:
– For unused DC connectors, push down the
clamping bracket and push the screw
connection up to the thread.
– Insert the sealing plug into the DC connector.
– Tighten the DC connector (torque: 2 Nm).
Sealing plugs
• Do not insert the sealing plugs directly into the DC inputs on the inverter.
+