beautypg.com

1 connecting the control voltage, Control voltage, Connecting the control voltage – SMA SC 500HE-US Maintenance Manual User Manual

Page 37

background image

SMA America, LLC

4  Maintenance

Maintenance Manual

SC500HEUS-eng-WH-IUS120411

37

4.4 Performing Maintenance Work on Inverters with Activated

Control Voltage

This section describes maintenance of the Sunny Central when the control voltage is switched on. The
inverter's component parts are energized. During the maintenance tasks described in this section it
may be necessary to turn the inverter off and then back on several times.

4.4.1 Connecting the Control Voltage

Figure 11: Position of the miniature circuit-breaker

%"/(&3

Str

Electric shock from live voltage
High voltages are present in the inverter and its component parts. Failure to heed this safety
message can result in severe or lethal injuries due to electric shock.

• Wear personal protective equipment.
• Follow instructions precisely.
• Observe safety messages.

Position

Designation

A

Miniature circuit-breaker for the external control voltage

B

Miniature circuit-breaker for the internal control voltage

C

Miniature circuit-breaker for the voltage meter

This manual is related to the following products: