beautypg.com

3 preparing the mounting location – SMA MULTICLUSTER BOX 12 User Manual

Page 15

background image

SMA Solar Technology AG

5  Installation

Operating Manual

MC-BOX-12-3-20-BE-en-10

15

Mounting position

Figure 6: Permitted and prohibited mounting positions

☐ The mounting location must allow compliance with the permitted mounting position.

5.3 Preparing the Mounting Location

Dimensions of the drill holes for fixing the Multicluster Box:

Figure 7: Outside base measurements and dimensions of the drill holes

Additionally required mounting material (not included in the scope of delivery):

☐ 4 suitable screw anchors to fasten the Multicluster Box to the support surface

Procedure:

1. On the mounting surface, mark the position of the four drill holes for attaching the base.
2. Drill holes at the marked positions.
3. Insert screw anchors.

:$51,1*

Danger to life due to fire or explosion
Despite careful construction, electronic devices can cause fires if they are not installed properly. Contact with flammable

materials allows the fire to spread. This can result in death or serious injury.

• Do not install the Multicluster Box on flammable construction materials.
• Do not install the Multicluster Box in areas containing flammable substances or objects.
• Do not install the Multicluster Box in potentially explosive atmospheres.