beautypg.com

Initial operation of the ik 115 – HEIDENHAIN IK-115 User Manual

Page 7

background image

,QLWLDO 2SHUDWLRQ RI WKH ,.

Initial Operation of the IK 115

Address settings

Configuring the board
Before you install the IK 115 in a PC, you must set the base
address of the board. The base address leaves the factory with
the base address 310H.

The IK 115 occupies 16 successive addresses in the I/O
address range of the PC. This setting should be exchanged only
if the I/O address range 310H to 31FH on your PC is already
occupied by another board.

In this case you must find a vacant I/O address range in your
PC. This address range must begin at a 16-byte segment
limit and can lie in the range of 000H to 3F0H. If you cannot
find the address ranges of other hardware in your PC, or if a
hardware conflict occurs, please ask your system
administrator or your computer dealer for help.

If necessary, you can set the new base address at the switch
row S1.

21

The switch positions are:

Switch number

1

2

3

4

5

6

Address line

A9

A8

A7

A6

A5

A4

Switch position

ON

OFF

Address line status

0

1