+DUGZDUH 'HVFULSWLRQ

Specifications of the IK 115

Specification of the PC bus
The IK 115 can be installed in all IBM AT and 100% compatible
PCs. HEIDENHAIN cannot guarantee proper function of the IK
115 in PCs that are not 100% compatible. The IK 115 complies
with the international standard IEEE P996, which specifies the
AT and ISA bus (industrial standard).

Bus width

16 bits

Power supply

+5 V ± 5%
+12 V ± 5%
–12 V ± 5%

Power consumption

Approx. 2 watts
without encoders

Slot version

AT-compatible, short 16-bit slot

Specification of the 1 V

PP

interface

Signal amplitudes
A, B (0°, 90°)

0.6 V

PP

to 1.2 V

PP

Signal level for error
message

ˆ 0.22 V

PP

Maximum input frequency

400 kHz

Cable length to encoder

Max. 150 m

Specification of the bidirectional EnDat or SSI interface

Input component

Differential line receiver
(e.g. LTC 485 or SN65LBC176D)

Input signals

Differential signals to RS 485

Terminating resistor

120

W

Maximum clock frequency

2000 kHz for EnDat interface
1000 kHz for SSI interface

Cable length to encoder

Max. 150 m