Setting up data interfaces

Serial interfaces on the TNC 320

The TNC 320 automatically uses the LSV2 transmission protocol

for serial data transfer. The LSV2 protocol is permanent and cannot

be changed except for setting the baud rate (machine parameter

baudRateLsv2). You can also specify another type of transmission

(interface). The settings described below are therefore effective

only for the respective newly defined interface.

Application

To set up a data interface, select the file management (PGM

MGT) and press the MOD key. Press the MOD key again and

enter the code number 123. The TNC shows the user parameter

GfgSerialInterface, in which you can enter the following settings:

Setting the RS-232 interface

Open the RS232 folder. The TNC then displays the following

settings:

Setting the BAUD RATE (baudRate)

You can set the BAUD RATE (data transfer speed) from 110 to 115

200 baud.