beautypg.com

Test run and program run 15.5 program run – HEIDENHAIN TNC 320 (77185x-01) ISO programming User Manual

Page 458

background image

Test run and program run

15.5 Program run

15

458

TNC 320 | User's Manual for DIN/ISO Programming | 3/2014

Example

The power failed while a thread cutting cycle in the tilted working

plane was being performed. You have to retract the tap:

Switch on the power supply for TNC and machine: The TNC

starts the operating system. This process may take several

minutes. Then the TNC will display the message "Power

interrupted" in the screen header

Activate the retraction mode Press the

RETRACT

soft key. The TNC displays the message

"RETRACT."

To acknowledge the power interruption, press the

CE key. The TNC compiles the PLC program.

Switch on external DC voltage. The TNC checks

the functioning of the EMERGENCY STOP circuit.

If at least one axis is not referenced, you have to

compare the displayed position values with the

actual axis value and confirm their agreement.

Follow the dialog, if required.

Check the preselected traversing mode: if required, select

THREAD
Check the preselected thread pitch: if required, enter the thread

pitch
Check the preselected direction of rotation: if required, select

the direction of thread rotation.

Right-hand thread: The Spindle turns in clockwise direction

when moving into the workpiece and counterclockwise when

retracting

Left-hand thread: The Spindle turns in clockwise direction

when moving into the workpiece and counterclockwise when

retracting

To activate retraction, press the

RETRACT soft key

Retraction: retract the tool with the machine axes keys or the

electronic handwheel

Z+: Retracting from the workpiece

Z-: Entering the workpiece

Exit retraction: return to the original soft-key level

End the retraction mode: press the

END

RETRACTION soft key. The TNC checks whether

the retraction mode can be ended. If necessary,

follow the dialog.

Answer the confirmation request: If the tool was not correctly
retracted, press the

NO soft key. If the tool was correctly

retracted, press the

YES soft key. The TNC hides the retraction

dialog.
Initialize the machine: if required, scan the reference points
Establish the desired machine condition: if required, reset the

tilted working plane