beautypg.com

2 showing the workpiece blank in the working space, Application, Showing the workpiece blank in the working space – HEIDENHAIN TNC 320 (77185x-01) ISO programming User Manual

Page 447

background image

Showing the workpiece blank in the working space

15.2

15

TNC 320 | User's Manual for DIN/ISO Programming | 3/2014

447

15.2

Showing the workpiece blank in the
working space

Application

This MOD function enables you to graphically check the position of

the workpiece blank or reference point in the machine’s working

space and to activate work space monitoring in the Test Run
mode of operation. This function is activated with the

BLANK IN

WORKSPACE soft key. You can activate or deactivate the function

with the

SW limit monitoring

soft key (2nd soft-key row).

Another transparent cuboid represents the workpiece blank. Its
dimensions are shown in the

BLK FORM table. The TNC takes the

dimensions from the workpiece blank definition of the selected

program. The workpiece cuboid defines the coordinate system for

input. Its datum lies within the traverse-range cuboid.
For a test run it normally does not matter where the workpiece

blank is located within the working space. However, if you activate

working-space monitoring, you must graphically shift the workpiece

blank so that it lies within the working space. Use the soft keys

shown in the table.
You can also activate the current datum for the Test Run operating

mode (see the last line of the following table).

Function

Soft keys

Shift workpiece blank in positive/negative

X direction

Shift workpiece blank in positive/negative

Y direction

Shift workpiece blank in positive/negative

Z direction

Show workpiece blank referenced to the

set datum

Switch monitoring function on or off

Note that even with

BLK FORM CYLINDER, a cuboid

is shown in the working space as workpiece blank.
When

BLK FORM ROTATION is used, no workpiece

blank is shown in the working space.