Error Messages

Message

Problem

AMPL. X TOO LOW

The encoder signal is too weak.
The scale may be contaminated.

INPUT ERROR

The entered value is not within
the permissible input range.

ERROR: REF. X

The spacing of the reference
marks as defined in P43 is not
the same as the actual spacing.

FRQ. EXCEEDED X

The input frequency for this
encoder input is too high. This
can occur when the scale is
moved too fast.

COMP. DELETED

Compensation values for non-
linear axis error compensation
erased.

PARAM. ERASED

Check the operating parameters.
If this error recurs, contact your
service agency.

PGM ERASED

The program has been deleted.
If this error recurs, contact your
service agency.

PGM TOO LARGE

The maximum program length is
99 blocks.

Message

Problem

OFFSET DELETED

Offset compensation values for
encoder signals erased.

PRESET ERASED

The datum points have been
erased. If this error recurs,
contact your service agency.

KEY W/O FUNCTION

This key currently has no
function.

TEMP. EXCEEDED

The temperature of the ND is too
high.

To clear error messages
When you have removed the cause of the error,
➤ press the CL key.

Error Messages