Switch-on, crossing over the reference marks – HEIDENHAIN ND 930 User Manual
Page 10

10
Switch-On, Crossing Over the Reference Marks
Switch-On, Crossing Over the Reference Marks
REF ? ENT ...CL
PASS OVER REF.
Turn on the power (switch located on rear
panel). REF and decimal points blink.
Press ENT before crossing reference marks.
Cross over the reference marks in all axes (in any
sequence). Each axis display becomes active
when its reference mark is crossed over.
0 ➨
➨
➨
➨
➨ 1
ENT
Crossing over the reference marks stores the last relationship between
axis slide positions and display values for all datum points in nonvolatile
memory.
Note that if you choose not to cross over the reference marks (by
clearing the dialog
REF ?
with the CL key), this relationship will be
lost if the power is switched off or otherwise interrupted.
You must cross over the reference marks if you want to use
the multipoint axis error compensation feature.
(See “Multipoint Axis Error Compensation”)