beautypg.com

HEIDENHAIN TNC 122 Technical Manual User Manual

Page 44

background image


4/97

TNC 122

11 Machine Parameters

43

Machine
Parameter

Function and input

Input value

MP4310

Setting a number in the PLC marker range
M2192 to M2211
Input values: 0 or 1

MP4310.0

X trav. direction 0=neg., 1=pos.

MP4310.1

Y trav. direction 0=neg., 1=pos.

MP4310.2

Z trav. direction 0=neg., 1=pos.

MP4310.3

Actual and nominal value transfer
in automated operational mode
0 = no, 1=yes

MP4310.4

1 = open position control loop
when override closed or NC stop

MP4310.5

Only effective if MP 4310.4 is active

1 = no controller enable when
override closed or NC stop

MP4310.6

1 = rapid traverse output O4 set
in automated operating mode

MP4310.7

1 = M05 output via O11
(M20/M21) and reset via M03,
M04, M13, M14;
M09 output via O10 (M22/M23)
and reset via M08, M13, M14

MP4310.8

0 = EMERGENCY STOP cancels
the SE outputs
1 = EMERGENCY STOP does not
cancel the SE outputs

MP4310.9

Position control loop
0 = NC control
1 = PLC control

MP4310.10

0 = M functions active in MDI
1 = M functions not active in MDI

MP4310.11

1= switch off PLC position
control loop monitoring

MP4310.12

1= rapid traverse information (MP
block) is not switched when the
advance switch point is reached

MP4310.13
MP4310.14
MP4310.15
MP4310.16
MP4310.17
MP4310.18
MP4310.19

A change to the machine parameters MP4310.x only becomes active after a power
interruption.